Cofferdam-assisted permanent repair

A sounding-point issue on an IACS-classed vessel was permanently resolved using a custom cofferdam and multi-stage verification.

34×34 CMSound area
50×50 CMCofferdam
4 TESTVerification

01 / REQUIREMENT

Field challenge

A controlled dry boundary was required for internal welding without unnecessary intervention to the surrounding structure.

02 / METHOD

Applied approach

  1. 01

    A 34 × 34 cm sound area was identified.

  2. 02

    A 50 × 50 cm cofferdam was installed with minimum disruption.

  3. 03

    An internal cut was made and the water drained.

  4. 04

    Ceramic backing was positioned and welding completed.

  5. 05

    Visual inspection, NDT, UT and vacuum tests followed removal.

03 / OUTCOME

Customer outcome

The repair passed four separate verification stages and was documented as a safe, permanent solution.